Application
Designed for air intake and extract systems of critical applications
such as Pharmaceutical and Electronic manufacturing and in Hospital
research laboratories where high efficiency filtration is necessary.
They are also used in Safe Change systems. HEPA filters are normally
used as final filters with pre filters fitted upstream to extend
their life. These filters are subjected to full quality assurance
procedures and each filter is individually leak tested, certified
and numbered for tracking.
Construction
Deep Pleat filters are designed to give the optimum combination
of high filtration efficiency and excellent dust holding capacity.
They consist of a deep pleat pack of filter media, sealed into
either a corrosion resistant coated mild steel or MDF case. The
filter pack is a continuous length of high efficiency water repellent
micro-fibre glass filter media, folded over aluminium or kraft
paper separators. It is then bonded to the case with a polyurethane
sealant to give a rigid and robust construction.
Range
Deep Pleat HEPA's are available with efficiencies between H10 to
H14, in a range of standard cases with nominal airflow rates up
to 3800m3/hr.
Deep Pleat Hepa Filters |
||||||||
|